Your hard hat is intended to protect you from which of the following? - correct answer Impact, penetration, and electric shock
Which standard is
... [Show More] imprinted on glasses or goggles that meet safety
requirements? - correct answer ANSI Standard Z87.1-2010
Which items of PPE do you need under normal working conditions (not
climbing)? - correct answer Hard hat, safety glasses, safety vest, FVD, and gloves
Which items of PPE would you need when working aloft on a ladder? - correct answer Hard hat, safety glasses, FVD, long-sleeved shirt, gloves, body belt,
positioning strap, and lineman's boots
What happens to leather when it is dried too fast in excessive heat? - correct answer The leather curls and cracks
How do you measure for proper "D" size on a padded body belt? - correct answer Measure hipbone to hipbone plus 2"
Once at the working height, pass the positioning strap around the pole
and engage the single-sided end on the D-Ring with the mouth of the
snap hook _____________. - correct answer Outward
Always verify visually that the snap hook has engaged the
__________________. - correct answer D-Ring
You must document your monthly PPE inspection on the applicable
inspection form. - correct answer True
What type of safety vest is required? - correct answer Class 3
What is the minimum clearance of CATV cable from power at the pole? - correct answer40 inches
What are the three indicators on the FVD? - correct answer10-step bar graph, audible tone, and power indicator LED
To use the FVD, after the self-test process, continue to hold pressure on
the power switch and move the FVD: - correct answer Toward the object you want to test
To replace the battery of the FVD, use this tool to pry the cover off the
back of the device: - correct answer Putty knife, coin or, small screwdriver
The FVD is only a voltage detector and is not intended to be a precision
measuring device. What other senses would you use as an additional
safety check? - correct answer Sight, sound, and smell
To determine if capacitive coupling is causing a hazardous voltage
indication, you should provide a temporary path to __________ for your
body to remove the voltage caused by the e-field of the power line. - correct answer Ground
Indications of high current include - correct answer Charring or melting of wires, and smoke
Metal buildings and mobile homes should normally indicate voltage is
present when tested. - correct answer False
How many times should you test a cyclic device, such as a traffic light
support strand? - correct answer Three complete cycles
When you ground yourself, the FVD should continue to indicate a
hazardous voltage. When the ground cord is released, the voltage will no
longer be detected. - correct answer False
Body Belt - correct answer Worn low on the hips
Eye Protection - correct answer Wrap-around style provides side
protection
Hard Hat - correct answer Prevents injury from electrical hazards
Safety Vest - correct answer Class III with reflective striping
Positioning Strap - correct answer Double-locking keepers
What is a breakaway clip used for? - correct answer Haul cable or rope to the working height
9" Side Cutting Pliers - correct answer Cuts RG-6 and RG-11 drop cables
Bell-Hanger Wood Bit - correct answer Equipped with a hole used to pull the cable
through
Locking Terminator Tool - correct answer Spring loaded action allows various brands to
be installed or removed
7/16" Open-end Torque Wrench - correct answer Properly tightens 'F' connector fittings
Can Wrench - correct answer Combination 3/8" and 7/16" socket
Which two tools are used to assist in routing aerial drop cables over
outdoor obstacles? - correct answer Lay Up Sticks Set, and Throwing Weights
House Box - correct answer Mount the ground block to this
2-way Splitter - correct answer Divides forward RF into two equal output
RG-6 Messenger Cable - correct answer For aerial runs of up to 150'
J-Hook - correct answer Hammered into a wooden pole
RCA Composite Cable - correct answer Passes baseband audio and video between
devices
The P-Hook is designed to tie no more than ___ aerial drop(s) to the
structure - correct answer1
What are primary functions of an SLM? - correct answer Measure broadband RF signal levels, and measure DC or splitter attenuation loss
All SLM devices have the same operating controls? - correct answer False
To accurately measure the power of a digital signal, you must measure
the _________ power of all frequencies in the channel. - correct answer Peak
What electrical values do most DMMs measure? - correct answer Voltage and resistance
Feet - correct answer Keep the ladder from sliding
Fly - correct answer Locks the extension section
Pawl - correct answer The upper backbone extension
Duty Rating - correct answer Label identifying the ladder grade
and type
When should a ladder be inspected thoroughly? - correct answer Before first use and each day, any time defects are suspected, and when it is new
When carrying a ladder more than 100 feet in windy conditions or over
unstable/slippery ground, which carrying method should you use? - correct answer Horizontal carry on the hip
When setting up an extension ladder against a building, which is the
correct height lean ratio listed below for the 4 to 1 rule? - correct answer Height 20', Lean 5'
To properly place a ladder leaning against a strand, what is the proper
adjustment for the strand hooks? - correct answer Engaged, turned toward the wide side of the ladder, away from you
Which step from the top of a step ladders or rung from the
top of an extension ladders should you not stand above? - correct answer2nd step/4th rung
A properly racked ladder should be visible from
the driver's seat and should not protrude? - correct answer More than two feet or less from the rear of the truck
Which preferred ladders are non-conductive and corrosion resistant? - correct answer Fiberglass
Which check is the best way to test a pole below ground level? - correct answer Prod
It is safe to descend a ladder with your back to the ladder. - correct answer False
___________ is a frequency-tuned voltmeter used to measure signal levels,
or power, at different channel frequencies. - correct answer SLM
Analog channels signal levels should be _____________ higher than digital
channel signal levels. - correct answer6 to 10 dB
DOCSIS downstream should be within _______ to allow for sufficient
margin at the cable modem. - correct answer-12 dBmV to +12 dBmV
The CNR of a video carrier is defined by measuring the video carrier and
measuring to the _____________. - correct answer Noise floor
What is the NTSC channel bandwidth? - correct answer6 MHz
What is the name of the DSAM test that can detect and display ingress
that has entered the drop or home wiring system? - correct answer Ingress Resistance
When troubleshooting the drop system using Ingress Resistance, where is
the advised location to begin? - correct answer At the tap end of the drop
What do DQI readings of 0 to 5 indicate? - correct answer Subscriber’s service being adversely affected by impairments
Ingress Scan detects and displays ingress in which frequency range? - correct answer4 MHz to 42 MHz
Full scan DSAM results can be displayed in which two formats to see the
channel numbers, video carrier levels, and analog video to audio deltas? - correct answer Graph and Table
Absolute power is the actual power level of a ______________. - correct answer Carrier
CNR stands for _______________. - correct answer Carrier to noise ratio
Charter's specification for hum is _______. - correct answer< 3%
When does Max Jitter occur? - correct answer When packets of data reach their destination out of order, resulting in
a jerky or jumbled playback
When using the Viavi One Check device, where can Ingress be tested? - correct answer At the Tap and ground block
Hum must be tested using a non-scrambled analog channel. - correct answer True
The Viavi OneCheck test can be performed at which location(s)? - correct answer At the tap, ground Block
and, CPE
The Viavi OneCheck test doubles overall test time when compared to
other SLMs. - correct answer False
Which of the following is not recommended when conveying energy and
confidence to a customer or non-sub? - correct answer Speaking slightly louder than normal
You should address the customer by their first name to promote a causal,
relaxed relationship. - correct answer False
True or false? Is this a statement of confidence? "I don't think that will be a problem." - correct answer True
Which of the following make up the three A's? - correct answer Acknowledge, answer, and act
True or false? Is using a lot of hand gestures an advised way to mange your reactions to an angry customer? - correct answer False
Lowering your voice tends to cause a calming effect on customers
because they will often lower their voice to match yours. - correct answer True
What is inflection? - correct answer The highs and lows in the pitch of your voice.
Emotions are contagious. - correct answer True
True or false? Is this a statement of clarifying a customer's problem? "What I heard you say is... Is that correct?" - correct answer True
Forming partnerships with the customer and letting them know you are
their advocate and not adversary is important. - correct answer True
Cable trespassing can occur in either underground or aerial construction. - correct answer True
The fascia board by itself is usually strong enough to support a P-Hook,
do not attempt to screw the hook into a lookout. - correct answer False
All aerial installations use flooded cable. - correct answer False
What are the guidelines that are used when splicing cables? - correct answer Use a maximum of two splices between the tap and bonding
demarcation, and use approved compression fitting and weatherproofing seals.
J-Hooks are often used at jump poles and span clamps are used at steel
stranded messenger. - correct answer True
Before proceeding inside of the house to install the customers
equipment, check the signal levels. If the proper levels aren't present, [Show Less]