Roof increaser correct answer: Fitting used to increase a vent pipe
Stack vented group correct answer: Vertical piping arrangement in which smaller
... [Show More] diameter trap arms are placed above larger trap arms which also serve as a vent
Soil pipe correct answer: Collects both human waste and other types of waste
Air gap correct answer: The unobstructed vertical distance thru air between a soil or waste pipe and the flood level rim of the fixture it discharges
Branch vent correct answer: Vent pipe that is connected at its lower end to two or more individual vents and at its upper end to open air
Developed length correct answer: The length along the centre line of a pipe including fittings is known as a
Fixture drain correct answer: Pipe that connects a fixture to the inlet of that fixtures trap is known as a
Nominally vertical correct answer: An angle of not more than 45 degrees on the vertical
Potable water correct answer: Safe for human consumption
Sewage correct answer: Any liquid waste other than clear water is known as
Storey correct answer: Interval between two successive floors or between a floor and the roof is known as a
Trap arm correct answer: Portion between the trap weir and the vent connection is known as the
Trap seal depth correct answer: Vertical distance between trap dip and trap weir
1-1/2 (38mm) correct answer: Min trap seal depth
Vent stack correct answer: Pipe that is connected at its lower end to the base of a stack and its upper end to open air is a
2 inch correct answer: What is the minimum size wet vent for a w.c.
3" correct answer: Every building has a stack vent of what size
Stack vent correct answer: A vent that is the extension of a soil or waste stack
2" correct answer: Branch size serving a tub and a lavatory is
225 degrees correct answer: Max turn distance on a w.c. Trap arm
Branch vent correct answer: A vent pipe connecting 2 or more individual vents
All waste water and clear water correct answer: Vertical waste stack may conduct
Symphonic action correct answer: Vents are installed to prevent trap seal loss caused by ________ ____
3 meters correct answer: Maximum lengthy of a w.c. Horizontal outlet
36" correct answer: Max distance between a fixture outlet and trap inlet is
210c 150 psi correct answer: When a t&p reliefs
300 mm from floor correct answer: Discharge pipe for t&p is within how far from a floor
Backwater valve correct answer: Must be full port normally open min 4"
Flood guard correct answer: Has to be automatic
Sump discharge piping correct answer: Union check valve full port gate or ball valve [Show Less]