1 Trillionth (10 ' 12) cycles - ANSWER-1 picohertz (pHz)
1 Billionth (10'9) cycles - ANSWER-1 nanohertz (nHz)
1 millionth (10'6) cycles - ANSWER-1
... [Show More] microhertz
1 thousand (10'6) cycles - ANSWER-1 milliheartz
1 cycle - ANSWER-1 HZ
V%R - ANSWER-What is the formula to find I when the values of V and R are known
Crosstalk - ANSWER-Is decreased by pairs twists, cable lay, shielding, and physical pair separation. Its values are typically a negative decibel value. closer to 0 more problems.
class 3/ 16 MHz - ANSWER-Category 3 is what class and frequency
class D/ 100 - ANSWER-MHzCategory 5e is what class and frequency
Class E/250 - ANSWER-Category 6 is what class and frequency
Class E/500 MHz - ANSWER-Category 6 A is what class and what frequency.
568.0 - ANSWER-Generic telcomuninications cabling for customer premesis.
568.0 - ANSWER-serves as the foundation for premises telecommunications cables infrastructure, enables the planning and installation of a structured cabling system for all types of customer premises.
intermediate cross connect - ANSWER-(IC) The connection point between a backbone cable that extends from the main cross connect (MC campus distributor (CD) first level backbone) and the backbone cable from the horizontal cross connect (HC floor distributor (FD) second level backbone).
LAN - ANSWER-Local Area Network
EF - ANSWER-Entrance Facility
ER - ANSWER-Equipment room
HC - ANSWER-Horizontal cross connect
MC - ANSWER-Main cross connect
work area - ANSWER-A building space where te occupants interact with telecommunications terminal equipment (an individual office or cubicle, printer/copier room.
Equipment room (ER) - ANSWER-Generally houses equipment that serves an entire, building, campus or customer.
Telecommunications room (TR) - ANSWER-An enclosed architectural space for housing telecommunications equipment, cable, terminations, and cross connect cabling.
Entrance Facility (EF) - ANSWER-The telecommunications service entrance to the building, including the entrance through the building envelope (exterior wall, ground level slab or roof) into the building interior and continuing to the entrance room.
Telecommunications Enclosure(TR) - ANSWER-A case or housing for telecommunications equipment, cable terminations and cross-connect cabling.
OSHA - ANSWER-Occupational Safety and Health Administration
ENT - ANSWER-electrical non metallic tubing
EMT - ANSWER-electrical metallic tubing
FMC - ANSWER-Flex metal tubing
FMT - ANSWER-Flexible metallic tubing
Telecommunication enclosure (TE) - ANSWER-A box or cabinet used to house telecommunications equipment. are often wall mounted but they are sometimes large enough to be floor mounted.
Telecommunications Room (TR) - ANSWER-A space that differs from equipment rooms (ERs) and entrance facilities (EFs) in that this space is generally considered a floor serving or tenant-serving ( as opposed to building or compus serving space that provide a connection point between backbone and horizontal cabling.
Omnidirectional - ANSWER-ensure the antenna is perpendicular to the ground
Semidirectinal - ANSWER-Verify antenna vertical or horizontal
What is the relationship between the number of the wire and the wires diameter? - ANSWER-The number of steps that were involved in the process of the wire drawing.
directional - ANSWER-Verify proper Asmith for proper angle some case lines of site
A gauge change of six numbers approximately - ANSWER-doubles or halves the conductor diamter
Capacitance - ANSWER-What is measured in farads (F) and causes a voltage difference between two wires when separated by insulation.
Impedance - ANSWER-Refers to the combined effects of resistance, inductive reactance of the conduit
Durability - ANSWER-A connectors ability to survive hundreds of insertion and withdrawal cycles is calculated as?
What are the 2 types of balanced twisted pairs. - ANSWER-Screen Shielded and shielded UTP and STP
100 Ohms at 100 MHz - ANSWER-What is the nominal characteristic impedance of balanced twisted pair cables?
4p4c 6p6c 8p8c - ANSWER-What are the 3 types of balanced twisted pair connectors
T568A T568B - ANSWER-What are the 2 standards compliant wiring schemes for 8p8c modular connectors
Series 11 - ANSWER-What type of coaxial cable is used in video back-bone distribution
F connector - ANSWER-What type of coaxial connector cannot be used with cable that have stranded center connector
3 piece crimp or screw on - ANSWER-Which type of BNC connector is NOT recommended for any installations
What is the purpose of a code - ANSWER-To ensure safety during the install and use of materiel components and fixture. Quality and Construction
What is the purpose of a standard - ANSWER-Defines process,producers, practices, or methods, and are developed to improve quality, functions,performances,repeatably or some of the fact of the item being defined.
Required - ANSWER-"Shall"
TIA-568-0- - ANSWER-DWhich ANS/TIA standard is the foundation for premises telecommunications cabling infrastructure
TIA-606 - ANSWER-Which ANS/TIA standard would you refer to locate labeling requirements and recommendations for the components of a structured cabling system.
TIA-607-C - ANSWER-Which standard is the primary standard for recommendations and requirements related to installing a telecommunication bonding infrastructure
2 - ANSWER-What is the minimum number of cables to a work area
Dmark - ANSWER-Orange is what termination field.
Network - ANSWER-Green is what termination field.
Purple is what termination field. - ANSWER-Common equipment
First level backbone - ANSWER-White is what termination field.
Second level backbone - ANSWER-Gray is what termination field.
Horizontal Cable - ANSWER-Blue is what termination field.
Inter building backbone - ANSWER-Brown is what termination field.
Miscellaneous - ANSWER-Yellow is what termination field.
Reserved for future use - ANSWER-Red is what termination field.
5m 16.5ft - ANSWER-The maximum length of of an equipment cord (not using a MUTOA.
Undercarpet cable - ANSWER-Not recomended cable
What is the purpose of a consolidation point - ANSWER-Allow horizontal cable to be extended imto work area pathways
Class 2 - ANSWER-Single building with multiple telecommunications spaces
Class 4 - ANSWER-Multiple sites with multiple buildings
Class 1 - ANSWER-Single building with one equipment room
Class 3 - ANSWER-Multiple buildings on the campus
Entrance facility EF - ANSWER-Where do outside plant (OSP) cables enter a building
Underground - ANSWER-What is the most economical permanent entrance over the life cycle of a building
Aerial - ANSWER-Which service entrance has the lowest installation cost
Equipment Room (ER) - ANSWER-Provides a controlled environment for the telecommunications equipment, connecting hardware and spice enclosures?
PAN, LAN, CAN, WAN - ANSWER-What are the most common networks encountered by and installer
Server - ANSWER-Manages one or more resources shared by workstations users and administrators on a network
Router - ANSWER-Network component makes it possible to segment a network into multiple broadcast domains
Network Software - ANSWER-What is used to transform a standalone computer into a network station
Server - ANSWER-Device is equipped with features not commonly found on desktop computers
Workstations - ANSWER-Device used to access an organizational network
Router - ANSWER-Device is a combination of hardware and software in the form of a device
Router - ANSWER-Name the device that that segments an organization network into multiple broadcast domains .
Work station - ANSWER-Which deice provides the user with the necessary interface for input and display.
Switch - ANSWER-Name a network access device that provides a centralized point for LAN communications
Switch - ANSWER-Which device can manage multiple types of resources or it can be dedicated to a single activity
Server - ANSWER-Which device can manage multiple types of resources, or it cn be dedicated to a single activity
Switch - ANSWER-Which device provide dedicated connection via port.
work station - ANSWER-What type of stations can be local or remote
Cloud storage or drive - ANSWER-Two most common methods used to back up a network
Every one present should know. - ANSWER-Who is responsible for knowing and flowing the company's safety policies
survey the scene - ANSWER-What the first step you should take when responding to a potential emergency
Compression connector - ANSWER-What coaxial connector is recommended
Screw on connector - ANSWER-What coaxial connector is not recommended
3 piece crimp or screw on - ANSWER-What type of BNC connector is not recommended for any installation
Class 1 - ANSWER-Single building with 1 equipment room is what class
Class 2 - ANSWER-Single building with multiple telco spaces is what class
Class 3 - ANSWER-Multiple building same campus
Class 4 - ANSWER-Multiple buildings on multiple sites is what class
Consolidation point - ANSWER-Allows horizontal cabling to be extended into work area pathways
Demarcation point - ANSWER-What is the term that identifies where the service provider relinquishes circuit responsibility to the customer
Entrance Facility - ANSWER-Where do outside plant enter the building
pan lan wan can - ANSWER-Most common types of networks encountered by installers.
Open Circuits Short Circuits wire pair missing wire drain wire - ANSWER-What problems can be identified using a wire map test for a UTP and STP cables
Verify Isolate repair and test - ANSWER-What are the steps for trouble shooting a cable system
3606 ft - ANSWER-What is the largest are a telecommunication room (TR) can serve
Faced - ANSWER-What type of cut over involves transfering portions` of the old system to the new system groups.
Phased cut over - ANSWER-Portions of the old system are transferred to the new system.
Flash cut over - ANSWER-One continuous process until cut over complete
Tone Generator,multi meter, Office locator kit, Certification test set - ANSWER-Name four testers that can be used for copper cable identification and tracing
Fiber flash light, light source,optical power meter, visual fault locator - ANSWER-Fiber [Show Less]