Elevator Mechanic Study Exam (Latest 2023 – 2024) Satisfaction Guaranteed
ASME - American Society of Mechanical Engineers
DOSH - Division of
... [Show More] Occupational Safety and Health
LADBS - Los Angeles Department of Building and Safety
Alteration made to conveyance shall comply with ASME A17.1-204 Section - 8.7
The seismic section of ASME A17.1-2004 and alterations made to conveyances must also comply with this section - 8.4
What must be submitted to the applicable Division Elevator office prior to beginning construction or alterations on a conveyance
Title 8 Sec 3000 - Letter of Intent
When shall Category One Tests on conveyances be completed
Title 8 Sec 3141.6 - Once every 12 months
What shall be provided on all conveyances regardless of the existence of an emergency stop switch
ASME A17.1-2004
2.27.1.2 - Audible signaling device
When are Hoist way door unlocking devices on all conveyances required
Title 8 Sec 3141.7
ASME A17.1-2004
2.12.6 - Prohibited
What section should Group IV platform lifts and stairway chairlifts shall comply with - ASME A18.1-2003
When setbacks or projections exceed this number of inches, occur in the enclosure wall, the top of the setback or projection shall be beveled at an angle not less than 75 degrees with the horizontal
ASME A17.1-2004
2.1.6 - 4 inches
At what height shall the hoist way enclosure of a Group IV elevator be Unperforated
ASME A17.1-2004
2.1.1.2.2 - 79 inches
For elevators installed after June 5, 1947, there shall be installed in the pit of each elevator where the pit extends below the sill of the pit access door a fixed vertical ladder. How many inches below the sill?
ASME A17.1-2004
2.2.4.2 - 35 inches
On a Group IV elevator, what is the minimum pit lighting illumination that should be provided at the pit floor
ASME A17.1-2004
2.2.5.1 - 10 fc (foot candles)
For Group IV elevators that are not fully enclosed, how high of protection should be provided on the hoist way sides that are located 59 inches or less from elevator equipment in areas accessible to other than elevator personnel
ASME A17.1-2004
2.2.1.3 - 94.5 inches
Permanent means shall be provided to prevent the accumulation of what? in the elevator pit
ASME A17.1-2004
2.2.2.3 - Water
In place of a sump pump, what else shall be provided on elevators equipped with Firefighters' Emergency Operation
ASME A17.1-2004
2.2.2.5 - Drain
On a Group IV elevator, how far shall a pit ladder extend no less than how many inches above the sill of the access door [Show Less]