5. A common factor with regard to multiple firefighter deaths at emergency incidents is: A. the lack of an organized, effective command structure
B. they
... [Show More] all involved industrial complexes
C. all the incidents occurred during forest fires
D. they all occurred in urban settings Correct answer- A. the lack of an organized, effective command structure
6. Which of the following is one of the stages/phases of fire burn?
A. Rollover
B. Fully developed
C. Backdraft
D. Initial Correct answer- B. Fully developed
7. Which of the following IS TRUE regarding personal protective clothing?
A. It requires firefighters to wear the most appropriate PPE for the hazard they face
B. It must comply with NFPA 1900 standard
C. It prevents a firefighter from burns in situations such as flashover
D. It requires PASS activation whenever bunker gear is worn Correct answer- A. It requires firefighters to wear the most appropriate PPE for the hazard they face
8. A fire CANNOT BE considered fully extinguished until is complete. A. overhaul
B. primary search
C. cause determination
D. secondary search Correct answer- A. overhaul
9. For an area to qualify as a light hazard, the majority of materials must meet one requirements. One of those is that they must:
A. be UL listed
B. have ignition temperatures in excess of 451F
C. be necessary for the work of the area
D. be noncombustible Correct answer- D. be noncombustible
10. What type of listening is required by a telecommunicator to draw out all the necessary information from a caller who may be excited, confused, or dealing with a language barrier?
A. Presumptive B. Active
C. Selective
D. Modal Correct answer- B. Active
11. After a roof has been opened up, the firefighter must:
A. remove any natural roof openings
B. make another opening on the opposite side of the pitched roof C. ensure the ceiling below the cut is opened
D. direct a hose line into the opening Correct answer- C. ensure the ceiling below the cut is opened
12. How are flammability limits and explosive limits related?
A. Explosive limits are used to calculate flammability limits
B. The two terms are neither mathematically nor conceptually related. C. They are interchangeable terms meaning the same thing
D. Flammability limits are used to calculate explosive limits Correct answer- C. They are interchangeable terms meaning the same thing
13. A load the engineer planned for, or anticipated, in the building design is the definition of a(n)
load.
A. dead
B. concentrated
C. impact
D. design Correct answer- D. design
14. What type of standpipe is intended for fire department use only?
A. Group 5 B. Type II
C. Class I
D. Level D Correct answer- B. Type II
15. What types of locking devices usually ARE NOT detected by the forcible entry team?
A. Mortise locks
B. Auxiliary locking devices
C. Padlocks
D. Rim Locks Correct answer- B. Auxiliary locking devices [Show Less]