Package deal Bundle for Fire Inspector 1 Exams Compilation... - $12.44 Add To Cart
6 Items
A gravity vent is part of which system in a building? - correct answer smoke management A multipurpose dry chemical extinguisher is rated for which clas... [Show More] ses of fire? - correct answer A, B, and C A performane-based code does what? - correct answer outlines a requirement that a design has to meet A stakeholder in a public fire safety program can be defined as: - correct answer an individual or group that is impacted by an issue According to NFPA 101, how are content hazards classified - correct answer low, ordinary, high although storage occupancies have low occupant loads, what do they have that causes concern for the fire department - correct answer high fuel loads An ________________ allows for the safe and orderly removal of people from a building in the event of fire or other emergency. - correct answer evacuation plan An extinguisher designed for Class A fires carries which color and shape symbol? - correct answer green triangle Drums can be manufactured from a variety of different materials. - correct answer true During which phase of a fire does flashover usually occur? - correct answer fully develped Exits must be _________. - correct answer remote from each other Extension cords are considered to be permanent wiring systems. - correct answer false Exterior stairs and fire escape stairs are the same thing. - correct answer false Found throughout a building, which building material is rarely used for structural support? - correct answer plastic General cleanliness of the interior of the structure is the only aspect of a fire inspection important to the fire inspector - correct answer false Glass is ___________, but it is not _________. - correct answer noncombustible, fire resistive How many different colored sections are in the Emergency Response Guidebook? - correct answer 4 How many different types of fire loads does a Type III construction have - correct answer 2 How many general categories of fire are there? - correct answer 5 How many major types of sprinkler system classifications exist? - correct answer 4 How many sleeping accommodations are required for an occupancy to be classified as a hotel? - correct answer 16 How many specific occupancy groupings are recognized by NFPA standards? - correct answer 15 How thick can wood posts in a heavy timber constructed building be? - correct answer 8" or larger If a dumpster or similar waste receptacle needs to be placed near a structure, what is the minimum distance it may be placed? - correct answer 10' If an exhaust system is required as part of the safety system in the building design, it is also required to be in continuous operation - correct answer true If the access passes through an area containing a fire hazard, the principle of free and obstructed exit access is violated - correct answer true In addition to activating the fire alarm and detection system, which other action will a duct-detector perform? - correct answer shut down the air-handling system if it detects smoke In many large buildings, what do fire alarm and detection systems also control in order to help protection occupants from heat and smoke - correct answer HVAC equipment in order to be classified as a high-rise, a structure will need to have occupied stores how high above the lowest level of fire department access? - correct answer 75' Occupant load is calculated based on the _______, not the occupancy type. - correct answer use of space Once a fire has ignited, which process must be created in order to keep the fire going - correct answer chemical chain reaction Since steel conducts heat well, it will tend to do what as temperature exposure increases? - correct answer expand and loose strength sprinkler system piping can be used for bonding an electrical system - correct answer false Stairway smoke management systems are required in which type of occupancy? - correct answer high-rise buildings the minimum number of exits necessary for an occupancy load of 1000 or more is - correct answer 4 The proper way to document a violation is to indicate both the _____ and _____. - correct answer violation, what needs to be done to correct it The purpose of the NFIRS is to collect useful national data on the many underlying factors in a fire. - correct answer true the weight of the building itself is referred to as the ___________, and the weight of the building's contents is referred to as the _______ - correct answer dead load, live load the width of any means of egress is usually not less than - correct answer 36" there is no one set of universal building, fire, or life safety codes across the united states - correct answer true Two common file folder formats used in the organization of fire inspection records are chronological and ___________. - correct answer functional What are examples of exit lighting that is required in many occupancies? - correct answer emergency lighting to illuminate means of egress what are some areas that are considered during an exterior inspection - correct answer vehicle access, fire lanes, sprinkler connections, hydrant access What are the four phases of fire development in their correct order? - correct answer incipient, growth, fully developed, decay What are the states of matter? - correct answer solid, liquid, gas What are the three types of main sprinkler valves? - correct answer alarm, dry-pipe, deluge what are the two terms used to describe the characteristics of flammable vapors - correct answer vapor density and flammability limits what are the two typical types of gas containers - correct answer cylinders and tanks What are two common causes of electrical fires? - correct answer arcing and overheating What assemblies of pieces of wood or wood-and-metal combinations often used to support floors and roofs? - correct answer wood trusses what chemical family is categorized as class 8 - correct answer corrosives What class of fire involves paper, cardboard, and other ordinary combustibles as its primary fuel type - correct answer class A What class of standpipe system is designed for use by only the fire department? - correct answer class I what color code is used on the bonnet of a fire hydrant that flows less than 500 gpm - correct answer red What defines a document that contains specifications or requirements defining the minimum levels of performance, protection, or construction - correct answer standard What designation of fire door would be required for use as part of a fire wall? - correct answer A What designation of fire door would be required for use as part of a stair shaft or elevator shaft? - correct answer B what do "as-built diagrams" show a fire inspector - correct answer how the final installation was actually completed What elements are required for a fire to occur? - correct answer fuel, heat, oxygen What exterior issues may limit the fire department's ability to identify the proper response location? - correct answer premise identification being blocked What fire alarm and detection system component is either an automatic or manually operated device that, when activated, causes the system to indicate an alarm? - correct answer alarm initiation device What is a benefit of a remote annunciator panel to a firefighter? - correct answer allows for quick location and type of alarm activation information to be displayed away from alarm panel What is a ducted HVAC system used for? - correct answer to distribute conditioned air fomr an HVAC appliance to the building area What is a method to reduce shock hazards by providing a path for stray currents and any accumulation of static electricity to flow? - correct answer grounding What is a self-supporting brick wall that does not carry part of the load of the building and is erected alongside the bearing wall considered to be? - correct answer veneer wall what is an apartment building - correct answer three or more dwelling units with independent cooking and bathroom facilities What is an area of refuge in relationship to an exit from a building? - correct answer a protected area designed for use by people with mobility impairements What is not a type of compressed gases and cryogenic fluids according to NFPA 55? - correct answer poison What is secondary containment engineered to do in relation to bulk storage containers? - correct answer control spilled or released products if the main vessel fails what is the correct name for packing material use to pack, support, and brace products within shipping containers - correct answer dunnage What is the fire department connection (FDC)? - correct answer a connection where the FD can pump water into a sprinkler or standpipe system What is the first phase of the plan review process? - correct answer approval what is the maximum projection at each side of a means of egress that is allowed by the Life Safety Code without impacting egress capacity calculations - correct answer 4 1/2, provided they do not occur at a height above 38" from the ground What is the minimum acceptable rating for fire extinguishers? - correct answer 2A10BC What is the minimum acceptable residual pressure in a water supply system that must be available for firefighting? - correct answer 20 psi What is the minimum distance that storage can be kept below sprinkler heads? - correct answer 18" What is the most common residential fire alarm and detection system in use today - correct answer single-station smoke alarm What is the most recent model building and fire prevention code name for the standard audio pattern produced by an alarm notification appliance? - correct answer temporal-3 pattern what is the name for the device used to hold multiple wires in walls and ceilings and that is typically made from metal pipes - correct answer conduit What is the name of the measurement device used to test water flow from a hydrant? - correct answer pitot gauge What is the name of the system that uses symbols rather than letters on the labels to identify the classification of fire extinguishers' use? - correct answer pictograph labeling system What is the principle hazard in hood and exhaust systems located above a cooking appliance? - correct answer accumulation of grease What is the principle use of a fuse - correct answer an overcurrent protection device What is the starting point used to measure travel distance to an exit? - correct answer the most remote point subject to occupancy what is the total electrical power that is available for use in an electrical system called? - correct answer watt what is type II construction also referred to as - correct answer noncombustible What marking or identification system is designed for fixed-facility use? - correct answer NFPA 704 What material is inherently fire resistive? - correct answer masonry What must be calculated after the occupant load has been determined? - correct answer the means of egress system What NFPA 13 hazard class includes occupancies that are ordinary, mercantile, manufacturing, and industry properties and that are placed into one of two groups? - correct answer ordinary hazards what NFPA 13 hazard class includes occupancies that have high-piled combustible stocks, flammable and combustible liquids, and materials that can permit the rapid spread of fire - correct answer special hazards What NFPA 13 hazard class includes occupancies that may produce severe fires - correct answer extra hazards what NFPA code identifies the specific occupancy groupings - correct answer 101 What NFPA code is the most widely used to determine building construction classification? - correct answer 220 What NFPA standard deals with the installation of sprinkler systems - correct answer NFPA 13 What NFPA standard governs the standard for portable fire extinguishers? - correct answer 10 What NFPA standard identifies the fire safety and emergency symbols used on plans? - correct answer 170 What number rating represents the highest hazard level in the NFPA 704 system? - correct answer 4 What occurs when an occupant travels a corridor, finds no exit, and is forced to retrace the path traveled to reach a choice of egress path? - correct answer a dead end exists What part of a building's construction bears the weight of the entire structure? - correct answer foundation What plan type will show the location of fire hydrants on a building property? - correct answer site What term defines whether a material will burn or not - correct answer combustibility What term is sometimes interchanged with "public education," and "public relations?" - correct answer public information What type of chemical reaction produces heat? - correct answer exothermic What type of construction feature supports other beams? - correct answer girder what type of construction features noncombustible exterior masonry walls and combustible nonstructural members such as walls, floors, and roof surfaces? - correct answer ordinary What type of construction is the most fire resistive category of building construction? - correct answer type I What type of fire department notification system has the fire alarm connected to a monitoring site owned and operated by the building owner? - correct answer proprietary supervising system What type of fire department notification system is a third-party, off-site monitored system? - correct answer central station system What type of fire inspection occurs to ensure compliance with fire code during and at the end of a building's construction? - correct answer construction what type of fire suppression system testing uses tanks of sample gases to make sure certain nozzles are directly pointed to cooking areas - correct answer hood and duct system What type of glass is made by molding tempered glass with reinforcing mesh to hold the glass together to prevent it from breaking? - correct answer wired glass What type of glass is manufactured so that a thin sheet of plastic is placed between two sheets of glass? - correct answer laminated glass what type of occupancy would be used for sheltering goods, merchandise, products, or vehicles - correct answer storage What type of permit is issued when an activity is going to take place for a specified period of time, such as a holiday costume store at a strip mall? - correct answer special use permit What type of plan set shows the overview of the lot that is being reviewed? - correct answer site what type of plan view shows a specific element construction or building feature in a larger scale, providing more clarity to the viewer - correct answer detail What type of plan view shows the exterior of the building and is labeled using the direction of the drawing - correct answer elevation what type of roof has sloping or inclined surfaces - correct answer pitched What type of smoke detector is triggered by visible products of combustion? - correct answer photoelectric What type of sprinkler head has a special coating such as wax or lead? - correct answer corrosion-resistant what type of sprinkler head is installed so that the water stream is directed downward against the deflector - correct answer pendent What type of sprinkler head is specially designed to discharge most of the water away from a nearby wall in a pattern resembling a one-quarter sphere? - correct answer sidewall What type of sprinkler head is specifically designed for use in a house and has a quick release and limited flow of water? - correct answer residential What type of sprinkler system is a type of dry system that, when activated, flows water from all heads at the same time because all of the heads are open? - correct answer deluge What type of sprinkler system is the most common and least expensive? - correct answer wet-pipe What type of sprinkler system requires a secondary device to activate, such as a smoke detector, before water will be released into the piping system? - correct answer preaction What type of wood-frame construction is no longer permitted without the presence of fire blocking - correct answer balloon what type or class of fire involves combustible metals - correct answer D What type or class of fire involves flammable or combustible liquids? - correct answer B What usually occurs during the commissioning step in plan review? - correct answer all of the buildings fire protection systems are tested When a building has an automatic fire sprinkler system, what must you make sure the system is matched to perform against? - correct answer content hazard level When a fire alarm and detection system if first installed, the fire inspector must observe the testing of the entire system prior to approving building occupancy. - correct answer true When an exit serves more than one story, how is the occupant load of each story considered when computing the required capacity of the exit at the story? - correct answer individually When would a variance or appeal be applicable in plan review? - correct answer when a project cannot conform to a section of code Where would the information regarding reinspection be located on a typical inspection report? - correct answer follow-up information which color in the NFPA 704 hazard identification system represents the area where a flammability hazard would be identified - correct answer red [Show Less]
Exterior walls and structural members that are of approved noncombustible or limited combustible materials and interior structural members constructed who... [Show More] lly or partly of wood are considered - correct answer Type III To protect steel structural components of a building, which of the following may be applied to protect the steel from heat? - correct answer Layers of gypsum board Curtain walls: - correct answer are nonbearing exterior walls Which of the following is a component in a required means of egress from normally occupied spaces? - correct answer Protected stairs unprotected noncombustible construction is: - correct answer generally limited to a maximum of two stories The ___________ plan shows the relative locations of walls, doors, windows and other features. - correct answer floor The common classifications of sprinkler systems include which of the following? - correct answer wet-pipe system Which of the following is a type of sprinkler system that maintains air under pressure in the sprinkler piping? - correct answer Dry pipe The color of a sprinkler head rated 500 degrees to 575 degrees, or "extra high" is" - correct answer Orange The color of a sprinkler head rated 250 degrees to 300 degrees or "high" is: - correct answer Blue Direct pumping water systems are those in which water: - correct answer is pumped directly into the distribution system The required residual pressure when computing available water supply in a specific are is _________ psi. - correct answer twenty Which detector is most apt to give a false fire indiction alarm when monitoring an area where arc welding is taking place? - correct answer Ultraviolet A(n) _____________ detector generally responds more quickly to smoldering fires. - correct answer photoelectric Smoke and fire dampers are typically located at points where: - correct answer HVAC ducts penetrate smoke and fire barrier walls Extinguishers suitable for Class A fires should be identified by a __________ containing the letter "A." If colored, it should be ____________. - correct answer tringle, green The common hazard associated with central heating appliances, unit heaters and room heaters is: - correct answer proximity of installation to combustibles To prevent accidental ignition of combustible material in a welding shop, which of the following actions should be followed? - correct answer Shop rags should be stored in metal containers When transferring flammable or combustible liquids, what precaution must be taken to prevent a spark due to static electricity? - correct answer Provide a bonding wire between the containers fire flow tests are made to determine the rate of fire flow available for fire suppression at various locations within the: - correct answer distribution system the interlocking network of water mains that compose a water distribution system is a: - correct answer grid or gridiron The system that is designed to provide constant pressure or flow when pipes on the grid must be repaired is called a: - correct answer grid or loop movement of water from a natural source, such as a lake into a reservoir, is facilitated by: - correct answer pumping stations Small structures that contain standpipe connections and hose lines reconnected to the discharge outlet are called: - correct answer hose houses The hose connections to the FDC must be of the ___________ type and equipped with caps. - correct answer Female A carbon dioxide extinguisher's principle means of discharge is: - correct answer Stored pressure Most buildings utilize a system of passive smoke control. When the compartmentation concept is used, ____________ shut down, and fire and smoke _____________ close to prevent the further spread of fire and smoke. - correct answer Fans; dampers Fire point is the minimum temperature required to: - correct answer ignite a liquid fuel in order to begin self-sustained combustion independent of the heating source Which of the following is provided in a fire flow test - correct answer Water flow pressures During a hydrant fire-flow test, water is discharged from a: - correct answer Flow hydrant The difference in the height of the water source and the point of use creates: - correct answer Elevation pressure A __________ consists of a network of pipes, storage tanks, control valves and hydrants. - correct answer distribution system Fire flow tests are made to determine the rate of fire flow available for fire suppression at various locations with the: - correct answer distribution system The principle pipe in a system of pipes for conveying water, especially one installed underground is a: - correct answer water main There are 4 main views of working drawings. they include: A. Divisional view B. Utility view C. Elevation View D. Orientational view - correct answer C. Elevation view Wood Frame or frame construction is commonly referred to as ___________ construction. - correct answer Type V In a new building, the minimum door opening in a means of egress is __________ inches. - correct answer 36 The measurement for maximum travel distance starts from the __________ portion of the occupancy, curving around any corners or obstructions with a _________ foot clearance, and ending at the center of the exit doorway. - correct answer Most remote; one One of the primary problems with external fire escape stairs is: - correct answer maintenance a fire wall must be continuous from the foundation floor to a height: - correct answer above the roof as required by the local building code Materials used for the exposed surfaces of the walls and ceilings of a building are usually known as: - correct answer interior finish NFPA recommends that fire hydrants flowing 1500 gym or greater be color coded: - correct answer light blue The terms bonding and grounding refer to the process of: - correct answer dissipating static charges Combustible dusts present a unique hazard because of their ability to form ___________ mixtures within an enclosure - correct answer explosive Heat that results from passing an electrical force through a conductor defines ____________ heating. - correct answer resistance [Show Less]
. The first step in the enforcement procedure would usually be to: A. notify the responsible party of his/her appeal rights. B. determine whether the vio... [Show More] lation is significant enough in nature to pursue. C. send the business owner a letter stating the premises are in full compliance. D. notify the responsible party, in writing, of all violations found - correct answer D Procedures in various jurisdictions may differ due to differences in the code enforcement each has adopted. These procedures should be A. restricted to a single typed page. B. designed to promote appeals. C. in detailed, written form. D. developed in a way that can be easily changed. E. maintained under strict security - correct answer C . Completed inspection reports are needed for every inspection because they: A. may be used for future code enforcement. B. are needed to complete the plan review. C. are used during community zoning hearings. D. indicate the effectiveness of the current inspection program. - correct answer A Which of the following is not helpful to consider when writing a letter? A. The reader will be reading the letter with interest. B. Use a natural and clear expression of thoughts. C. Maintain an awareness of the thoughts, feelings, and impressions that might be evoked when the recipient reads the letter. D. Remember not to think in terms of the letter being a substitute for an actual conversation. - correct answer D . _________________ are a way of staying aware of changes in use or hazardous conditions. A. Surveys B. Permits C. Self-inspections D. Fire reports - correct answer B On a site plan, the north directional symbol usually points toward the: A. magnetic North Pole. B. right side of the page. C. top of the page. D. true North Pole - correct answer C . There are four main views of working drawings. They include all of the following except the _________________ view A. sectional B. utility C. elevation D. detailed E. plan - correct answer B When a citizen calls to report a suspected fire hazard, fire inspectors should: A. record all pertinent information. B. file the complaint for future action. C. forward the complaint to the Board of Appeals if immediate corrective action is required. D. consider the motivation for the complaint. - correct answer A When investigating a complaint, a fire inspector should: A. never give the owner advance notice of the investigation. B. explain the purpose of the investigation to the owner. C. take appropriate departmental action to correct the violations. D. Both B and C are correct. - correct answer D When an individual building or business owner feels that the local jurisdiction has made an improper code interpretation or decision, the individual may request a: A. hearing in district court or civil court, depending on the degree of hardship. B. hearing by the civilian review board. C. review by the Board of Appeals. D. more favorable ruling by the building inspector. - correct answer c Prior to a court case, an inspector should do all of the following except: A. reinspect the facility the day before the trial. B. go over his/her testimony with the prosecutor before entering the courtroom. C. appear in proper uniform or be neatly dressed. D. volunteer information to make responses as detailed and complete as possible - correct answer D . Which of the following is not suggested for courtroom procedure or behavior? A. Never become argumentative on the witness stand. B. Make sure that all physical evidence, exhibits, photographs, notes, and reference materials are brought to court. C. Attempt to answer a question you do not know. D. Remain impartial. Do not give the impression that you have a personal dislike for the defendant. - correct answer C . According to NFPA 101, Life Safety Code, a building that provides sleeping facilities for four or more residents and is occupied by persons who are generally prevented from protecting themselves because of security measures not under their control, is classified as a/an: A. residential occupancy. B. occupancy of unusual structure. C. industrial occupancy. D. detention and correctional occupancy - correct answer D . According to NFPA 101, Life Safety Code, buildings used as a store, market, and other rooms, buildings, or structures used to display and sell merchandise are classified as a/an: A. mercantile occupancy. B. business occupancy. C. storage occupancy. D. place of assembly. E. occupancy of unusual structures - correct answer A Fire drills in educational occupancies should not be conducted: A. during classroom changes, since the students are already in the hallways. B. during assembly programs, since the students are all in one place making for easy evacuation. C. during lunch time. D. at the start of each day. - correct answer D The purpose of school fire exit drills is to: A. increase speed in evacuating all children. B. instill discipline and order. C. ensure that all exits are being used and are not locked. D. ensure orderly exit of all personnel under controlled supervision. - correct answer D A sketch depicting the general arrangement of the property in reference to streets, adjacent properties, and other important features is known as a: A. plot plan. B. sectional view. C. floor plan. D. blueprint. - correct answer A Which item would not be considered during a field observation of a site for emergency access? A. Fire department access roadways which are wide enough to permit fire apparatus to operate and to pass B. Verification of code compliance for the storage, handling, and use of hazardous materials C. Physical, topographical, or architectural obstructions D. Adequate turning radius E. Whether access roads are within minimum building access distance requirements - correct answer B . The temperature at which a liquid fuel, once ignited, will continue to burn is known as: A. fire point. B. vapor temperature. C. boiling point. D. flash point. - correct answer A When a fuel gives off enough vapors so that it can be ignited and burn momentarily, it has reached its: A. fire point. B. upper flammable limit. C. vapor density. D. flash point. - correct answer D Class B fires involve fuels such as: A. greases or flammable/combustible liquids. B. energized-electrical equipment. C. combustible metals. D. ordinary combustibles. - correct answer A When referring to the L.E.L. of a flammable or combustible liquid, what does the L.E.L. mean? A. Lowest Efficiency Level B. Life-Span Equivalency Label C. Lower Explosive Limit D. Lowest Evaporation Limit - correct answer C The upper and lower concentrations of a vapor that will produce a flame at a given pressure and temperature are called: A. flash points. B. vapor densities. C. flammable and explosive limits. D. burning points. - correct answer C The percentage of a flammable substance in air that will burn when in contact with an ignition source best defines: A. ignition temperature. B. boiling point. C. flammable/explosive limit. D. flash point. - correct answer C Vapor density is used to evaluate the relative weights of _________________ in much the same way as specific gravity is used to evaluate _________________. A. solids, liquids B. air, solids C. gases, liquids D. liquids, air - correct answer C Choose the best answer regarding the difference between compressed and liquefied gases at normal temperatures. Within a pressurized container: A. compressed gases are in both a liquid and gaseous state. B. compressed gases are only in a gaseous state. C. liquefied gases are only in a liquid state. D. liquefied gases are in a gaseous state only. - correct answer B In a closed area, gases with vapor density of less than one will: A. rise and not concentrate near the ceiling. B. rise and concentrate near the ceiling. C. settle and not concentrate at the floor. D. settle and concentrate at the floor. - correct answer B Vapor density is defined as the weight of _________________ as compared to the weight of an equal volume of _________________: A. gas, air. B. air, gas. C. liquid, air. D. air, liquid. - correct answer A On above-ground inside storage tanks for flammable or combustible liquid storage tanks, automatic closing, heat-actuated valves are required on: A. all piping connections. B. piping connections above the liquid level. C. none of the piping connections. D. all piping connections below the liquid level. - correct answer D Inside storage tanks containing Class I, II, or III-A liquids must have vent pipes which terminate: A. outside of building. B. at least 12 feet above tank. C. at least 5 feet above tank. D. at least 3 feet above fill pipe. - correct answer A Containers that are approved for flammable and combustible liquids should have how many devices that will provide sufficient venting capacity to limit the internal pressure of the containers to 10 psi or 30 percent of the bursting pressure of the container? A. One or more B. Three or more C. Four or more D. Not required - correct answer A The diked area surrounding above-ground flammable liquid storage tanks must have a volume large enough to contain: A. the volume of half of the tanks within the diked area. B. half of the volume of the largest tank. C. entire volume that could be released from the largest tank. D. the volume of all the tanks within the diked area. - correct answer C Dip tank operations must be located in noncombustible buildings. At what floor level in noncombustible buildings must dip tank operations be located? A. Not above the third floor. B. Not above the second floor. C. Not below the ground floor. D. Not above or below the ground floor. - correct answer D To avoid trapping cryogenic liquids in piping, which choice for installed piping is the safest? A. A pressure relief device every 100 ft and piping sloped up from the container. B. A pressure relief device between every two shut-off valves and piping sloped up from the container. C. A pressure relief device every 90 ft and piping sloped down from the container. D. A pressure relief device between every two shut-off valves and piping sloped down from the container. - correct answer B The objective of a residential inspection program is to: A. attain proper life safety conditions. B. prevent fires. C. educate the property owner and occupants about fire safety. D. All of the above. - correct answer D The colder of two bodies will always absorb heat until both objects are the same temperature is explained by the Law of _________________ which is a natural law of physics. A. Specific Heat B. Heat Transfer C. Latent Heat of Vaporization D. Atomic Weight - correct answer B The principle which most closely describes how water extinguishes fire is: A. removal of fuel. B. reduction of temperature. C. exclusion of oxygen. D. inhibition of a chain reaction. - correct answer B During the first phase of a fire, the oxygen concentration within the room contains approximately _________________ percent oxygen. A. 10 B. 16 C. 20 D. 79 - correct answer C A fire in the presence of a higher than normal concentration of oxygen will: A. burn slower than normal. B. burn faster than normal. C. not be effected by the oxygen. D. not burn if oxygen is too rich - correct answer B _________________ is electrical heat energy resulting from inadequately insulated electrical materials. A. Dielectric heating B. Induction heating C. Frictional heat D. Leakage current heating - correct answer D Mechanical heat energy initiated by the movement between objects in contact with one another defines: A. dielectric heating. B. heat of friction. C. static electricity. D. resistance heating. - correct answer B The amount of heat generated through the process of oxidation is known as: A. heat of solution. B. heat of decomposition. C. heat of combustion. D. spontaneous heating - correct answer C Heat that is released by the mixture of matter within certain liquids is known as: A. heat of solution. B. heat of decomposition. C. heat of combustion. D. spontaneous heating. - correct answer A Heat that results from passing an electrical force through a conductor defines _________________ heating. A. resistance B. dielectric C. induction D. frictional - correct answer A Heating of an organic substance without an external heat source is known as: A. spontaneous heating. B. heat of decomposition. C. dielectric heating. D. frictional heat. - correct answer A The release of heat usually due to bacterial action best defines: A. spontaneous heating. B. heat of decomposition. C. heat of compression. D. heat of solution - correct answer B The three methods of heat transfer are: A. conflagration, combustion, and contact. B. fuel, heat, and oxygen. C. conduction, radioactivity, and direct flame contact. D. convection, conduction, and radiation - correct answer D The concept of heat flow specifies that heat: A. will flow from a hot substance to a cold substance. B. will flow from a cold substance to a hot substance. C. will vaporize a liquid thereby also reducing itself. D. can travel through a building by one of four methods - correct answer A In order to have spontaneous heating, the substance must be: A. insulated. B. organic. C. inorganic. - correct answer B The two types of valves found in water supply distribution systems are: A. gate and indicating. B. ball and check. C. screw and yoke. D. indicating and non-indi - correct answer D The four fundamental components of a modern water system are: A. source, mains, feeders, and risers. B. primary, secondary, standpipes, and subscriber connections. C. pipes, valves, hydrants, and pumps. D. source, treatment plant, means of moving, and delivery system - correct answer D In an assembly area of less concentrated use, such as a conference room or dining room measuring 150 feet by 200 feet, what would be the occupant load, if a load factor of 15 sq. ft. per person is used? A. 1,000 B. 2,000 C. 500 D. 5,000 - correct answer B The primary method used in determining the occupant load of a structure or part of a structure is the _________________ method. A. floor area B. building height C. occupancy classification D. building exit E. aisle - correct answer A During an inspection of a building, the first area to be inspected should be the: A. roof. B. basement. C. interior. D. exterior. - correct answer D . A self-closing fire door is one that: A. closes when heat activates the closing device. B. closes by magnetic controls. C. after being opened, returns to the closed position. D. is a Class B door only - correct answer C In terms of life safety, two of the most important functions of doors are to: A. provide light and fresh air in case of a fire. B. provide access for the fire and police department in times of an emergency. C. help with the ventilation and confinement of the fire. D. act as a barrier to fire and smoke and serve as components in a means of egress - correct answer D That portion of a means of egress between the termination of an exit and a public way is an exit: A. passage. B. path. C. access. D. discharge. - correct answer D The minimum number of exits required from any story or portion thereof with an occupant load of 500 or less shall be: A. 4. B. 2. C. 5. D. 3. - correct answer B . _________________ fixed fire extinguishing systems are similar to halon systems in that they are primarily used to protect against fires involving flammable gases or liquids and in electrical equipment. A. Chemical [Show Less]
All of the statements about the administrative duties of a fire inspector are TRUE EXCEPT: - correct score The administrative work of the fire inspector is... [Show More] typically delegated to the fire chief Before you plan a meeting: - correct score Make sure that the meeting is the best way to accomplish your objectives The reference library provides the authority in guidance for the inspection, maintenance, and testing for all of the following except: - correct score Pumper apparatus criteria An asterisk found in an NFPA standard refers to: - correct score Explanatory material on that paragraph located in the code appendix or annex A family housing briefing should include a: - correct score Discussion of escape plans from the home Identify THREE forms that may typically be found in a facility folder - correct score Inspection checklist Record of an inspection that includes fire safety discrepancies and fire hazards Self-help approvals Which statement describes department of defense (DoD) instruction 6055.06 - correct score Establishes the foundation for fire inspection and education programs Play these reference documents in the order of precedence if a conflict exists - correct score UFC 3-600-01 National Fire codes DoD technical guidance (ETLs, IMTs, technical policies) The goal of an effective fire safety education program is to: - correct score Change behaviors in a way that results in fewer fires, if you were injuries, and less property loss All of the following guidelines for wearing safety equipment are TRUE EXCEPT: - correct score Full-face self-contained breathing apparatus should be worn in areas when you suspect improper storage and mixing of hazardous chemicals Which statement is TRUE regarding work request approvals? - correct score They are required to make modifications to the building Identify TWO ways educated members of the community can prevent or reduce life and property loss - correct score Recognizing and eliminating fire safety deficiencies in their homes and offices Taking appropriate actions during an emergency All of the following will help you to minimize interruptions successfully EXCEPT: - correct score Refusing to respond to office visitors An example of a fire hazard is: - correct score A frayed or damaged electrical extension cord with exposed wiring placed under a rug The service specific item that contains a checklist of areas/systems to inspect is: - correct score The fire prevention/protection record Identify THREE ways to ensure a successful closing interview - correct score Start with the favorable items;then explain the problems End on a positive note Provide instruction on the recording/reporting procedures The MAIN purpose of the local fire alarm system is to: - correct score Alert occupants to evacuate the premises safely The NFPA manual that covers the use, insulation, and maintenance of fire extinguishers is: - correct score NFPA 10 The type of alarm system most likely to result in a direct dispatch a fire personnel to a fire scene is: - correct score A remote supervising station alarm Use of a portable fire extinguisher with a rating of 4-A, 20-B:C on: - correct score Ordinary combustibles, flammable liquids, and energized electrical equipment A violation that is identified and corrected during an inspection is written up in the inspection records/report as: - correct score Correct on the spot A central station fire alarm system: - correct score Ties several remote local alarm systems into a central location FM-200-174 is a: - correct score Clean agent Dry sprinkler heads should be tested AT LEAST once every: - correct score Ten years A burning 6 amp motor should be extinguished with a: - correct score Class C fire extinguisher CO's main utility as an extinguishing agent is its: - correct score Smothering capacity The kind of smoke detector that uses a pump to draw air samples into a high-humidity chamber is a: - correct score Cloud chamber air sampling detector The extinguishing agent most effective in a fire involving animal or a vegetable oils is - correct score Wet chemical The MINIMUM temperature that must be maintained in order to use a wet pipe sprinkler system is: - correct score 40° F (4° C) The piping for a dry chemical system is normally made of: - correct score Metal Signs marking the path of egress are SOMETIMES required at: - correct score Floor proximity. NFPA 204 states the requirements for: - correct score Smoke and heat vents One possible place to find evidence of potentially hazardous flyings is the: - correct score Heating system inlet grate. Cooking equipment must be kept away from combustible materials by a distance of at least: - correct score 18 inches (46 cm) The clearance between a newly installed handrail and a wall cannot be less than: - correct score 1 inch (25 mm) A building is being constructed in the petroleum oil liquid (POL) storage area. The class of roof covering that should be used for protection against this severe hazard is: - correct score Class A When inspecting an HVAC system check the ducts for: - correct score Smoke detectors Unlike firewalls, fire partitions extend from - correct score One floor to the underside of the floor above Chipping and coating area exhaust ducts must: - correct score Follow the most direct route to the discharge Every month, emergency lighting should be tested for at least: - correct score 30 seconds Type IV construction is commonly referred to as: - correct score Heavy timber The part of an exhaust system that removes residue is the: - correct score Filter At a minimum, exhaust systems must be inspected by a responsible party at the facility: - correct score monthly Identify TWO ways you may be able to determine whether a decorative material meets NFPA requirements - correct score Perform a field flammability test Reading the label Piping that carries hazardous liquids to a dipping in coating area must be made of: - correct score Latex In determining the means of egress, an occupant load of less than 200 persons requires a maximum of ___ exits - correct score 2 According to the Life Safety Cod 174, a facility that is used to teach 7th grade math classes to groups of 25 students is classified as: - correct score An educational occupancy The occupant load factor (in square feet per person) for a building that is used by a telemarketing firm is: - correct score 2.8 The occupancy classification that BEST describes a hospital is: - correct score health care occupancy The maximum heat they can be produced if all the combustible materials in a given area burn is known as the - correct score Fire load Doors and windows allowed in a firewall are referred to as: - correct score Protected openings The means of egress must be illuminated at a minimum of ___ foot-candle(s) - correct score one Light fixtures in a dipping and coating area must be sealed in order to prevent: - correct score Vapors from escaping The purpose of a fire wall is to: - correct score Prevent the spread of fire within a structure The force to open panic hardware on a fire exit cannot exceed: - correct score 15 lbf Identify the TWO ways by which the hazardous contents of a building are classified - correct score Character of the contents Processes or operations conducted in the building In a cooking exhaust system, the filter will be found in the: - correct score Type I hood All of the following are examples of mercantile occupancies EXCEPT - correct score Auction rooms (cdc test says Law offices though) According to NFPA 1, Fire Code, the minimum clearance for a fire lane is: - correct score 13 feet, 6 inches (4.1 m) Places the steps for performing a graphical analysis of water flow test results in the correct order. - correct score A) determine which flow (gpm) scale to use B) locate the residual pressure noted during the test and plot the residual pressure above the water flow measured C) locate the total water flow measured during the test D) locate and plot the static pressure at zero gpm E) read the gpm available at 20 psi F) draw a straight line from the static pressure point through the residual pressure point To compute hydrant flow, you must know the coefficient of discharge (based upon the shape of the hydrant outlet), the diameter of the hydrant, and: - correct score The pressure read at the hydrant orifice. The "brain" of a fire alarm system is the: - correct score Control panel (cdc tests says the heat sensing device) On a sprinkler system, the clapper valve is found in the: - correct score Alarm valve When inspecting the distribution main in a sprinkler system, pay careful attention to all components because the distribution main is the pipe that: - correct score Provides the water supply for the system. Water flow pressure is the: - correct score the forward velocity of water at the discharge point The person normally assigned to make a heat count at an exit drill gathering area is the: - correct score Evacuation monitor The best way to test dude evacuation plans is to conduct: - correct score Regular fire exit drills When inspecting the outside of the alarm control panel, begin by: - correct score Ensuring that the system has power All weather ground access has to be available on ___ side(s) of a building? - correct score 2 The formula used for determining available water using the mathematical method is the: - correct score Hazen-Williams formula Identify THREE variables that determine travel distance to a particular fire extinguisher - correct score Type of fire extinguisher Hazard content classification Size of the fire extinguisher A looped feed fire hydrant: - correct score Is supplied from two or more directions Water main valves are used to: - correct score Control the flow of water in the system Do you need to determine the goal of your writing before you write so that you can focus on your writing and: - correct score Keep extraneous information out of the document Which statement is TRUE regarding a plans review? - correct score It allows code enforcement to begin before construction begins Before you testify as a witness, it's a good idea to: - correct score Meet with an attorney to go over your testimony An item that may be useful as evidence in legal proceedings is: - correct score An inspection report DoD agencies are directed to adopt policies for records management and disposition by; - correct score DoDD 5015.2 During an inspection, you walk inside a building where automobiles are stored. Such storage indicates the need for: - correct score A permit or written approval How should a fire inspector handle customer complaints? - correct score Ensure that each complaint is documented The best way to organize your time each day is with: - correct score Daily planner Identify THREE ways a fire inspector should prepare for an inspection - correct score Review the facility folder for the building to be inspected Use the reference library to research the codes and standards that apply to the facility or structure Contact the building manager to arrange a time for the inspection Today you are conducting an inspection for the base education center. Upon arrival at the center, you explain that the primary goal of the inspection is to: - correct score Ensure the safety of the occupants Identify THREE ways to achieve fire prevention "buy in" in the community. - correct score Exchange information with other agencies Create positive impressions Conduct fire prevention demonstrations Identify THREE items to take with you on an inspection - correct score A clipboard with the inspection forms A flashlight Tape measure On an initiating device, the design requirement that prevents light flame detectors from alerting too easily is the: - correct score flickering action One difference between a dry pipe system and a wet pipe system is that: - correct score Water in a dry pipe system is held back by air pressure, while a wet pipe system has water throughout In a sprinkler system, water is distributed directly to branch lines by: - correct score Cross mains During the inspection of a hood and duct fire suppression system, the only visual clue that the system is either a wet chemical system or a dry chemical system is the: - correct score Type of nozzles being used. The type of extinguishing agent no longer being manufactured is: - correct score Halon The class of fire extinguisher that bears this symbol is: - correct score Class K A building with a large glass atrium would best be served by using a: - correct score Rate compensation detector A sign with letters required to be not less than 6 inches (15 cm) high and at least 2 inches (5 cm) wide is: - correct score An externally illuminated exit sign A fire load classified as "moderately severe" by the national Institute of standards and technology (NIST) is typically: - correct score 10 to 15 psf (50 to 75 kg/m2) The gross floor area of a building that is 40 feet long by 25 feet wide is: - correct score 1,000 square feet The maximum height for doorway sills is: - correct score 1/2 inch (1 1/4 cm) Your primary concern when inspecting chimneys is whether the chimney: - correct score Provides suitable removal of waste gases When more than one exit is needed in an on sprinklered room or building, exit should be separated by at least one half the ___ distance of the room - correct score Diagonal Before the occupant load for a building can be calculated, you must know the: - correct score Square footage and use of the building Structural sections of a spray area can be sealed with: - correct score Latex-based caulk Identify TWO ways to determine the fire load of a building - correct score Divide the total estimated pounds of combustible material by the square footage of the building Use the classification system for fire loads developed by the National Institute of Standards and Technology (NIST) Ventilation systems for dipping and coating areas must be installed in accordance with: - correct score NFPA 34 Determine the occupant load for an elementary school classroom that has no fixed structures or seating. The floor area of this classroom is 600 ft.² - correct score 14 people The primary difference between types I and II construction is that type II construction: - correct score Provides a lesser degree of fire resistance The purpose of a dry pipe valve is to: - correct score Keep water out of the sprinkler system until a fire activates the sprinkler During a water flow test, the flow hydrant should be located: - correct score Downstream from the test hydrant Identify THREE fire alarm system initiating devices - correct score Flame detector [Show Less]
The floor in spray booths must be made of? - correct answer non-combustible materials Specifies fire codes and standards that are adipted and implemente... [Show More] d by all DOD fire departments - correct answer UFC 3-600-1 establishes the foundation for fire prevention and education programs - correct answer DoD instructions 6055.06 2 ways to handle interruptions - correct answer leave box for people to drop off paperwork that needs a signature Allow voice mail to answer your calls when you're working on a high priority item 5 time bandits - correct answer failure to plan day interruptions procrastination poorly planned meetings inefficiency Name the 3 major tool types of a fire inspector - correct answer reference library functional tools what do these mean in NFPA publications: 3.3.1 * line of the side Dot between paragraphs - correct answer code standard number * explanatory material in appendix line- new changes dot - paragraph deleted provides minimum requirements to ensure a reasonable degree of safety to life form fire in building and structures. - correct answer NFPA 101 life safety handbook color-coded description of fire alarm systems and it includes recommendations for efficient compliance with the requirements of NFPA 72 - correct answer national fire alarm and signaling code handbook describes proper electrical systems and equipment installation for compliance with NFPA 70 national electrical code - correct answer national electric code handbook provides a comprehensive description of fire safety and systems. - correct answer fire protection handbook Describes fire hazards and provides recommendations for identifying and correcting problems. Also, provides checklist for inspections - correct answer NFPA inspection manual provides technical info and assistance to the construction industry and code enforcement community - correct answer Fire resistance design manual provides training for the fire service - correct answer IFSTA manual provides guidance for the design and construction of buildings and building systems - correct answer international building code IBC Provide engineering criteria for planning, design, construction, sustainment, etc... of DoD facilities - correct answer UFCs Are ETLs and ITMs commercial publications? - correct answer no The publication that establishes the fire protection engineering policy and criteria for DoD components - correct answer UFC 3-600-01 examples the ilustrations that help you interpret and enforce the codes - correct answer NFPA handbook How long should your tape measure be? - correct answer 50ft 5 steps of an inspection - correct answer arrival exterior inspection interior inspection report/record closing interview When you start an inspection? - correct answer After meeting the building manager Must you write up all FSDs even if they corrected on the spot? - correct answer Yes. But write corrected on the spot During the closing interview make sure the building manager: - correct answer understands any interim or corrective actions that should be taken A condition which reduces the fire safety below the acceptable level, including noncompliance with standards, but itself cannot cause a fire to occue. - correct answer Fire safety deficiency Name 3 functional areas of a fire inspector's duties - correct answer Admin, field inspection and plans review delay, defer and postpone are all words used to describe? - correct answer procrastination the purpose of the fie safety code is to provide ________ requirements for a reasonable degree of safety to life form fire in buildings and structures. - correct answer minimum There is conflict between UFC 3-600-01 and a DoD technical guidance. What is the proper course of action. - correct answer Apply the DoD technical guide most commonly found sprinkler systems and are filled with water at all times - correct answer wet pipe system How is the water held back in dry pipe systems? - correct answer pressurized air Major drawback to wet systems? - correct answer the delay in water systems installed in warehouses, barns and parking garages - correct answer dry-pipe systems Where are pre-actions systems installed? - correct answer where potential water damage is a concern dry systems in which the water supply valve is opened on a signal from a detection device like heat or smoke detector. - correct answer pre action system systems that are installed where there is a great posibility of flash fire or rapid fire growth. - correct answer deluge systems dry systems with open sprinklers - correct answer deluge name the 6 considerations for sprinkler systems - correct answer thermal sensitivity temp rating orifice size installation orientation water distribution characteristics special service conditions name the six basic types of fire suppression systems - correct answer dry chem wet chem gasrous extinguishing systems standpipe systems water spray systems sprinkler systems used when there is requirement for a rapid fire knockdown and when the likelihood that the fire can reignite is minimal. - correct answer dry chem system name some areas where a dry chem system is used - correct answer flam/com liquids and gases solids that melt when burning electrical hazards grease hoods, duct, and cooking appliances textile ops What are a few things where dry chem is not applicable? - correct answer chems that contain their own O2 combustible metals deep-seated fires in ordinary combustibles sensitive electronics standard for dry chem systems - correct answer NFPA 17 name the 4 types of dry chem systems - correct answer total flood local application hand hoseline pre-engineered dry chem system that is fixed that discharges a predetermined amount of dry chem through the piping and nozzles into the protected area until empty. - correct answer Total flood dry chem systems that have nozzles that are arranged and aimed directly at the potential sources of fire. They are normally used to protect open tanks of flammable liquids or cooking oils - correct answer local application dry chem system that consists of one or more hand hoselines. - correct answer hand hoseline system name the 3 classes of dry chemicals are approved for use for fire suppression - correct answer sodium bicarbonate salts of potassium multipurpose chemicals standard for wet chem extinguishing systems - correct answer NFPA 17A Name the 3 types of gas extinguishing systems - correct answer halon, CO2, clean agent standard for halon fire extinguishing systems - correct answer NFPA 12 what kind of fires is halon effective towards? - correct answer class b and c name a few disadvantage of halon systems - correct answer depletes the ozone can be toxic difficult to replace whats the main utility as an extinguishing agent of CO2 - correct answer smothering what is the biggest disadvantage of CO2 systems - correct answer can be fatal standard for clean agents - correct answer NFPA 2001 Gases that do not harm the ozone - correct answer clean agents what gas is ineffective on cellulose nitrate? - correct answer CO2 what gas has the lowest capacity for leakage - correct answer clean agents Standard for install of standpipe and hose systems - correct answer NFPA 14 Which class of standpipe is designed for fire department personnel? - correct answer Class I , 2.5 inch line Which class of standpipe is primarily used by building occupants? - correct answer Class 2 1.5 inch line Which class standpipe is for both fire personnel and occupants? - correct answer Class 3 A special fixed pipe system connected to a fire protection water supply and equipped with water spray nozzles for specific water discharge and distribution over a specific area or piece of equipment. - correct answer water spray system What kind of sprinkler heads does a water spray system use? - correct answer deluge type. Name the two basic functions of all fire alarm systems - correct answer 1. detection heat, smoke or flames 2. Signaling - audible/visual alarms Name three others things fire notification systems can do - correct answer recall elevators to ground floor actuate smoke removal or stairwell pressurization fans shut down specified air handling systems What must every alarm system that runs off AC electricity have? - correct answer a secondary power supply Name the five major types of alarm systems - correct answer Auxiliary proprietary supervising station local remote supervising station central station This Alarm is used in communities served by a municipal fire alarm box. It sends a signal directly to a fire dept or dispatch center - correct answer Auxiliary This alarm system has a central recieiving point staffed continually with trained personnel. Good for complexes such as campuses, industrial complexes. - correct answer proprietary supervising station fire alarm system How many operators must there be present for a proprietary system? During what hours? - correct answer 2 24 hrs a day Alarm used to detect a fire and sound an alarm on premises only - correct answer local alarm system Alarm systems that are connected directly to the FD dispatch center or other answering service either by phone or radio frequency - correct answer remote supervising station fire alarm system In a remote supervising station alarm system, the annuciator panel would typically be found in the? - correct answer fire station Alarm system that ties several remote local alarm systems into a central location - correct answer central station fire alarm system In a central station alarm system, the FD is directly connected to the? - correct answer central receiving station alarm console Name the five basic components of an alarm system - correct answer control panel alarm initiating device notification appliance power sources aux devices the brain of a fire alarm system - correct answer the control panel name the basic 6 types of alarm initiating devices - correct answer manual pull heat detectors smoke detectors flame detectors suppression systems combination What part of an alarm system can notify fire department of an alarm and also do things like venting stairwells and returning elevators to ground floors? - correct answer Aux system the device that originates the alarm signal - correct answer initiating device Name the 3 heat sensing detectors - correct answer fixed temp rate compensation rate of rise Which heat detector works fastest - correct answer rate-of-rise The signaling system that is unique to fixed temp detectors - correct answer glass bulbs filled with solvents name the three types of smoke detectors - correct answer ionization, photoelectric, air sampling initiating device that monitors a small amount of air from the protected area in order to detect smoke particles - correct answer air sampling smoke detectors name the two flame detectors - correct answer light detector, thermopile detector What is a major drawback to light detectors - correct answer can be triggered by a non-fire stimulus A flame detector is the least effective type of detector for? - correct answer a smoky, smoldering fire standard for portable fire extinguishers - correct answer NFPA 10 name the 5 classes of fire extinguishers - correct answer A - ordinary B flammable c energized electrical D combustible metals K combustible cooking media whats the largest numerical rating for a class A extinguisher - correct answer 40-A What agents can Class B extinguishers have? - correct answer foam, carbon dioxide, dry chem, halogenated, clean agents what is the rating range for a class b extinguisher? Whats this rating based off of? - correct answer 1-b - 640 B, square area it cause extinguish What agent do class D extinguisher contain? - correct answer dry powder what does a 4-A, 6-B rating mean on an extinguisher - correct answer 4x the 1-A , or 6x 1-B Standard for fire exinguishers - correct answer NFPA 10 how many temp classifications are there for sprinkler heads? - correct answer 7 Name the 2 classes of dry chemicals approved for use as agents - correct answer salts of potassium, sodium bicarbonate In a propietary supervising station fire alarm, the alarm system is owned by? - correct answer building owner What detector will cause an alarm to sound whenever the rate of temp rise exceeds about 15 degree? - correct answer rate-of-rise Whats the most common combination detector? - correct answer rate-of-rise/fixed temp detector Fire alarm system that is connected to a municipal fire alarm system for transmitting an alarm to the public - correct answer an auxiliary whats a major disadvantage of a truss? - correct answer if one fails they can all fail and the rest are comprimised type I construction - correct answer fire resistive construction Type II - correct answer fire non-combustible or limited combustaible construction standards of types of building construction - correct answer NFPA 220 the period of time the assembly will perform satisfactorily when exposed to the fire test. - correct answer extends from one floor to the underside of the floor above. Vertical fire barriers. - correct answer fire partitions fire resistance rated wall with protected opening that extends from the foundation to the roof - correct answer fire wall constructed of non-combustibl materials and fastened to the ceiling. - correct answer draft curtain/curtain board Where can you find the requirements for all modifications, additions and remodeling projects? - correct answer UFC 3-600-01 where are occupancy classifcations identified? - correct answer LIfe safety code buldings used for gatherings of 50 people or more - correct answer assembly colleges are educational occupancies T or F - correct answer false provies medical services or treatment simultaneously to four or more people - correct answer ambulatory health care occupancy differs from a residential occupancy in that this facility provides lodging and boarding for the purpose of providing personal care services. 4 or more residents who are not related to the owner - correct answer residential baord and care occupancy occupancy used for the display and sale of merch - correct answer mercantile Under 50 people, used for business, includes universities - correct answer business occupancy first step in determining occupant load - correct answer know the square footage how do you calculate gross floor area? - correct answer legnth x width gross floor area - area of the fixed contents - correct answer net floor area floor area/occupant load factor - correct answer occupant load occupant load = area - ocuupant load factor - correct answer 3 main elements of means of egress - correct answer exit, exit access, exit discharge means of egress that leads to an exit - correct answer exit acess part of means of egress that is located between the termination of an exit and a public way - correct answer exit discharge buildings are required to have a protected path from the foot of an erxit stairway to the exit . - correct answer exit enclosures part of the means of egress that is separated from all other interior spaces of a building by resistant construction - correct answer exit passageways proctected place where persons unable to use an exit can remain temporarily to wait for instructions or assistance during an emergency evacuation - correct answer areas of refuge How many means of egress are required for a building with more than 500 people but not more than 1k? What if it has more than 1K? - correct answer 3 means 4 means for 1k+ Spaces between an occupied room and a means of egress, such as a kitchen, closet, bedroom etc.. - correct answer intervening rooms there can be no dead ends in ________ - correct answer corridors or hallways Hallways that are used in means of egress - correct answer corridors Can elevators be used as egress? - correct answer yes with certain conditions met whats the minimum headroom in all rooms with objects ? - correct answer 6'8'' a dead is allowed in a unsprinklered hallway if the dead-end hallway is less than? - correct answer 20 ft Headroom minimum on a new ceiling - correct answer 7' 6'' Headroom for stairs min? - correct answer 6'8'' What can rule out a elevator as a means of egress - correct answer if the general public uses the tower Whats the min required clear width for doors? - correct answer 32 in clear width/ capacity factor (found in NFPA 1001) - correct answer calculations for egress components, use the smallest figure to determine egress numbers Force needed for panic hardware cannot exceed? - correct answer 15 lbs Actuating portion of panic hardware must be located between? - correct answer 34-48 inches min stair width in new construction? If less than 50 occupents? Min for existing stairwells? - correct answer 44 in, 36 in 36 in _______ are required on both sides of all ramps and stairs. At what height? - correct answer 34-38 inches from ground Hangers that hold sprinkler piping should be spaced in accordance with? - correct answer NFPA 13 Min height of gaurds - correct answer 40 in, 36 in in old cunstruction artificial illumination for means of egress has to be lit at a value of at least? - correct answer 1 foot-candle Emergency lighting tests are required at intervals of? - correct answer 3 to 5 weeks 3 major guidelines for NEW externally illuminated EXIT signs - correct answer letters must be 6 inches, proportional letters to height, directional indicator must be visible at 40ft. Standard for ventilation control and fire protection of commercial cooking operations - correct answer Is there filter in type II hoods? - correct answer No filters to replace How often should fusible links be replaces on Type I system for automatic fire extinguishing equip - correct answer At least annually Standard for HVAC systems install - correct answer NFPA 90A two things you must inspect in a/c systems - correct answer smoke detector in ducts, dampers In a dipping process area, which system should automatically shut down if a fire is detected? - correct answer pump in the supply pipe Interior wall and ceiling finishes come in what ratings? - correct answer class A - FSI 0-25, SDI 0-450 Class B - FSI 26-75, SDI 0-450 Class C - FSI 76-200, SDI 0-450 [Show Less]
The inspector must have a through knowledge and understanding of the following items: - Enabling legislation, State/Local Statues, ways to alter State/Loca... [Show More] l Statues The personnel given the responsibility for fire and life safety inspections programs are members of the: - Fire Department Categories of Inspections are: - Annual (Routine), Issuance of a permit, Response to a complaint, Eminent hazard, New Construction, Change in Occupancy, Owner/Occupant Request At the time of inspection the inspector should: - invite the building owner/occupant Federal buildings in the local jurisdiction are - not required to comply with local codes The development and implementation of codes are a result of a cooperative effort among: - Fire department administration, Mayor or city/county manager, Municipal legislative body, Legislative body Occasionally, it is prudent to obtain written permission to enter a site before inspection. The use of a: - Consent-To-Enter form will remove questions [Show Less]
$12.44
101
0
Beginner
Reviews received
$12.44
DocMerit is a great platform to get and share study resources, especially the resource contributed by past students.
Northwestern University
Karen
I find DocMerit to be authentic, easy to use and a community with quality notes and study tips. Now is my chance to help others.
University Of Arizona
Anna Maria
One of the most useful resource available is 24/7 access to study guides and notes. It helped me a lot to clear my final semester exams.
Devry University
David Smith
DocMerit is super useful, because you study and make money at the same time! You even benefit from summaries made a couple of years ago.
Liberty University
Mike T