Your role is to ensure the safety and serviceability of the stockpile and monitor AE uploads, transportation, and storage activities. Who are you? -
... [Show More] ANSWER-QASAS
You have been appointed as your installation's safety chief. Who is responsible for developing, implementing, and managing the ESP as part of the overall safety and occupational health program for the installation? - ANSWER-installation commander
If you are responsible for assisting commanders and staff with resolving explosives safety concerns, which role do you have? - ANSWER-safety specialist
You are assigned to support tactical units regarding execution of ESMP. Who are you? - ANSWER-Ammo Warrant Officer
The installation commander assigns one person as the POC for all ESMP activities. Which role does that person fill? - ANSWER-Safety cheif
Colonel hires you as the occupational safety and health manager by what reg? - ANSWER-DA PAM 385-64
UXO can be generated - ANSWER-in combat, live fire range, discarded by military munition
UXO safety procedures - ANSWER-don't touch, keep away, notify
ammo life cycle field - ANSWER-RDT&E, production, storage, ASP, range
ammo life cycle theater - ANSWER-port, storage, ASP, AHA, operational units
DDESB's mission - ANSWER-create DoD ESP, ESP oversight, advise Secretary of Defense about ESP progress
cardinal rule - ANSWER-expose minimumamountof people, minimum amount of explosives, and minimum amount of time
after ammo leaves reserve, where does it go next? - ANSWER-ASP
what happens to unusable ammo? - ANSWER-demilitarization
document check list - ANSWER-DoDD 6055.09E, DoDI 6055.16, AR 385-10, DoDD 6055.09M, DA PAM 385-64
You are working on new ES guidelines for the Army. What key principle should you remember? - ANSWER-service standards can be more restrictive but not less than DoD
Where are the minimum level protection regulations found for ES in all services? - ANSWER-DoDD 6055.09M
advantages of DU - ANSWER-hard, easy to fabricate, dense, inexpensive, pyro
calibers of DU - ANSWER-20mm, 25mm, 30mm, 105mm, 120mm
HC 1.1 primary hazard is? - ANSWER-mass detonation
what is the primary hazard for mass fire? - ANSWER-1.3
If a vehicle is transporting a load of frag grenades, what signs would it have? - ANSWER-1.2
If a vehicle is transporting a load ammo with fire risk, what signs would it have? - ANSWER-1.4
What are uses for DUs? - ANSWER-aircraft counterweight, kinetic energy projectile, protective armor plating, radiation shield material
basic ops inside an ammo magazine - ANSWER-banding and marking
basic ops outside an ammo magazine - ANSWER-removing grommets, plugs; air testing; unpacking
An organization on your installation is preparing to deploy. Your team must prepare the ammo for them. Which operations are you permitted to do INSIDE a magazine? - ANSWER-inventory, inspecting, shipping
You must remove and replace grommets on AE at an ECM. How far from the exterior side of the ECM do you have to perform this task? - ANSWER-50ft
You are tasked to unpack, link, and repack SAA at an AGM. How far from the AGM do you have to be to perform this task? - ANSWER-100ft
You are inspecting an AGM and the ammo is stacked pretty high. What is the minimum required distance it can be stacked from the ceiling? - ANSWER-18 inches
You know the safety office is conducting random inspections of magazines. Which of these ammunition storage guidelines apply? - ANSWER-ammo can't touch walls an exit can't be blocked
Ammo encounters electrical energy from - ANSWER-lightening, circuits, static, electromagnetic
conductive floors are tested - ANSWER-after installation, renovation, semi-annually
Dumley just finished reviewing the SOP. How often does he need to inspect conductive flooring? - ANSWER-daily
When does Dumley need to test his conductive shoes? - ANSWER-daily, at issue
You will be working in the ammo operations area today. Which clothing material should you wear to prevent static? - ANSWER-cotton
Which is a common source of static electricity? - ANSWER-steam, air, materials passing through chutes, moving parts
controlled burns - ANSWER-100 ft away, building ventilators must be closed, rear vent of ECMs must be covered, hoses ready
You need to ensure there are firebreaks around your AGMs. What is the minimum distance the firebreak must be from each AGM? - ANSWER-50ft
While clearing a magazine for fire prevention you notice there are no fire extinguishers in any of the magazines. How many hazard-specific fire extinguishers must be readily accessible where ammo is being handled? - ANSWER-2
You are scheduling a controlled burn to prevent fires. This activity must be located at least how many feet away from an open storage area or building handling ammunition? - ANSWER-100ft
You are inspecting a magazine and it has no fire symbols. You know the DODIC has the abbreviation BBC beside it. Which Fire Symbols should be on the magazine? - ANSWER-symbol 1 set 2
You must inspect several operating buildings. Which of these is a requirement for operating building exits? - ANSWER-self closing doors that swing outward
You are working on a protective construction design. All of these are considerations you must make for AE storage and operating buildings EXCEPT - ANSWER-container locks
One of your facilities requires a change in NEW requirements. Can you modify an approved construction design to meet NEW requirements for it? - ANSWER-No
Risk Management Process - ANSWER-identify, assess, develop, implement, supervise [Show Less]