The main difference between a laundry tub pump and a sump pump is
(a) laundry tub pumps can handle lint
(b) sump pumps are laundry capacity
(c) laundry
... [Show More] tub pumps operate on 120 volt, and sump pumps operate only on 240v power
(d) sump pumps are manual, and laundry tub pumps are automatic ✔✔(a) laundry tub pumps can
handle lint
All of the following are common HRV problems
except
(a) missing filters
(b) dirty heat exchanger core
(c) lack of a trap in the condensate drain
(d) flow measuring stations located on warm side ducts ✔✔(d) flow measuring stations located
on warm side ducts
Squeaking subflooring is an indication of
(a) over spanned joists
(b) undersized beams
(c) poor fastening of subfloors
(d) undersized subfloors ✔✔(c) poor fastening of subfloors
High efficiency gas furnaces installed in old ductwork tend to have
(a) higher maintenance
(b) excess temperature rise
(c) shorter life spans
(d) all of the above ✔✔(c) shorter life spans
Most radiant heating systems are located
(a) in the ceiling
(b) in the floors
(c) on exterior walls below windows
(d) in light weight concrete panels ✔✔(a) in the ceiling
Which group of terms does not go together?
(a) pier, column, truss
(b) rafter, truss, purlin
(c) joist, beam, girder
(d) stud, header, sill ✔✔(a) pier, column, truss
The cable is protected by 60-amp breakers at the main panel. You should make sure that
(a) the cable is protected in a ventilated metal raceway
(b) the cable is in rigid conduit
(c) the cable is no longer than three feet
(d) the subpanel is rated to handle at least 60 amps.
(d) the subpanel is rated to handle at least 60 amps. ✔✔(d) the subpanel is rated to handle at least
60 amps.
If there is no water in the boiler, the low water cutouts prevents the
(a) circulator from operating
(b) burner from firing
(c) pressure reducer from adding water
(d) entrapment of air in the air separator ✔✔(b) burner from firing
A house has service entrance conductors designed for 100 amps and a main disconnect rated at
100 amps. Which of these conditions is unsafe?
(a) The service entrance box is rated at 125 amps
(b) The service box is rated at 75 amps
(c) The distribution panel is rated at 125 amps
(d) The distribution panel is rated at 200 amps ✔✔(b) The service box is rated at 75 amps
Which of the following steam systems is commonly converted to hot water?
(a) A one pipe, up-feed system
(b) A one pipe, down-feed system
(c) A two-pipe system
(d) A one pipe, parallel flow system ✔✔(c) A two-pipe system
All of the following are basic components of a masonry wood-burning fireplace except
(a) A damper
(b) A throat
(c) A smoke shelfs
(d) A heat circulator ✔✔(d) A heat circulator
Copper-tube boilers typically have:
a) Better heat transfer characteristics, and longer lifespans than cast-iron boilers
(b) Better heat transfer characteristics, but shorter lifespans than cast-iron boilers
(c) Worse heat transfer characteristics, but longer lifespans than cast-iron boilers
(d) Worse heat transfer characteristics, and shorter lifespans than cast-iron boilers ✔✔(b) Better
heat transfer characteristics, but shorter lifespans than cast-iron boilers
Which of the following is a similarity between furnaces and boilers?
(a) Piping
(b) A low-level safety device
(c) High-temperature limit switches
(d) Backflow preventers ✔✔(c) High-temperature limit switches [Show Less]