There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers ✔✔6
Bathtubs should be equipped
... [Show More] with the waste outlets and overflow outlets connected to piping at
least _____ inches in diameter ✔✔1.5 inches
Doors between the garage and residence shall be equipped with a ✔✔Self-closing door
The _____ shall not be considered as an effective ground-fault current path ✔✔Earth
For natural ventilation for habitable rooms, the min openable area to the outdoors shall be _____
percent of the floor area being ventilated ✔✔4%
Fuel gas appliance connectors shall not exceed an overall length of _____ feet ✔✔6 ft.
What size are fuel-gas-fired domestic clothes dryer ducts ✔✔4 inches
The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons.
✔✔660 gals.
The minimum bet area of ventilation openings shall not be less than _____ square foot for each
_____ square feet of under-floor space ✔✔1 sqft. for each 150 sqft
Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of
_____ inches into concrete or grouted cells of concrete masonry units ✔✔1/2 in. , 7 in.
Outdoor and return air for a forced-air heating and cooling system shall not be taken from
✔✔Closets, bathrooms, toilet rooms, kitchens, garages, boiler rooms, furnace rooms,
unconditioned attics, or other dwelling units
Receptacles installed on 15 and 20 ampere rated branch circuits shall be on the _____ type
✔✔Grounding
Ceiling-suspended paddle fans shall be supported ________________ of the outlet box.
✔✔independently
Dwelling units shall be provided with heating facilities capable of maintaining a minimum room
temperature of ✔✔68 *f
Conductors in NM cable assemblies shall be rated at _________ Celsius. ✔✔90 *C
Address numbers shall be a minimum of _____ inches high with a minimum stroke width of _____
inch. ✔✔4 inches , 1/2 inch
Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and portions of
basements containing these spaces shall have a ceiling height of not less than _______ feet. ✔✔7
feet
A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the
highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. ✔✔5 feet
Open web truss or I-Joist floor assemblies require a ____-inch gypsum wallboard membrane,
____-inch wood structural panel membrane, or the equivalent on the underside. ✔✔1/2 And 5/8
Flanges and lips of load-bearing cold-formed steel floor framing members shall not be cut or ____.
✔✔Notched
Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point
where they pass through the roof. ✔✔2 feet
Foundations for masonry chimneys shall be constructed of concrete or solid masonry at least _____
inches thick ✔✔12 inches
Supports and foundations for the outdoor unit of a heat pump shall be raised at least ___ inches
above the ground. ✔✔3 inches
Attic ventilation openings shall have a least dimension of _________ inch minimum to _________
inch maximum openings. ✔✔1/16 And 1/4
All wood beams, joists, studs and other combustible material shall have a clearance of not less
than _____ inches from the front faces and sides of masonry fireplaces. ✔✔2 inches
The minimum headroom in all parts of the stairway shall not be less than _____ feet, _____ inches
✔✔6 feet, 8 inches
A nosing not less than ____ inch but not more than ____ inches shall be provided on stairways
with solid risers. ✔✔3/4 And 1 1/4
Unattached decks not exceeding _____ square feet in area, that are not more than _____ inches
above grade do not require a permit. ✔✔200 sqft. And 30 inches
Gas appliance shut off valves shall be located in the same room as the appliance and not further
than _____ feet from the appliance ✔✔6 feet
BTU is abbreviation for _____ _____ ______, which is the quantity of heat required to raise the
temperature of 1 pound of water 1*F ✔✔British thermal unit
Stairways shall not be less than ____ inches in clear width at all points above the permitted handrail
height and below the required headroom height. ✔✔36 inches
An automatic fire sprinkler system is not required when _____ or _____ are made to existing
townhouses that do not have a sprinkler system ✔✔Additions and or Alterations
Chimney shall extend at least _____ feet higher than any portion of a building within ____ feet.
✔✔2 feet, 10 feet
Window wells serving emergency escape and rescue openings shall be designed for proper ____.
✔✔Drainage
Braces wall panels shall be constructed with intermittent bracing method s, or the continuous
sheathing methods. Mixing of bracing methods shall be ______. ✔✔Permitted
Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).
Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).
A thermal barrier is not required for foam plastic insulation in an attic that is entered only for
purposes of _____ or ______. ✔✔Repairs or Maintenance
ANy portion of a masonry chimney located in the interior of a building or within an exterior wall
shall have a minimum air space clearance to combustibles of _____ inches. ✔✔2 inches
The provisions of Section R505 Steel Floor Framing shall control the construction of cold-formed
steel floor framing for building not greater than ____ feet in length perpendicular to the joist span.
✔✔60 feet
For rooms with sloped ceilings, at least ____ percent of the required floor area of the room must
have a ceiling height of not less than 7 feet. ✔✔50%
Where raceways are installed in wet locations above grade, the interior of such raceways shall be
considered to be a ______________ location. ✔✔Wet
Perforated foundation drains shall be surrounded with an approved ____ ____. ✔✔filter membrane
Chapter 11 regulates the ___________ efficiency for the design and construction of buildings
regulated by this code. ✔✔Energy
A pane of glass in a window requires safety glazing if the pane is greater than ____ square feet
with a bottom edge less than ____ inches above the floor and top edge greater than ____ inches
above the floor. ✔✔9 sqft., 18 inches, 36 inches
The connection between a deck ledger and a 2 inch nominal lumber band joist shall be constructed
with _____ inch lag screws or bolts with washers ✔✔1/2 inch
At the intersection of asphalt shingles with a vertical sidewall, flashing shall be a minimum of
_____ inches in height and ____ inches in width. ✔✔4 inches, 4 inches
The markings for identification of disconnecting means shall have the durability to withstand the
_____ involved. ✔✔environment
A _____ shall be provided at the base of each waste or soil stack ✔✔Cleanout
All mechanical elements used to terminate a grounding electrode conductor or bonding jumper to
the grounding electrodes shall be __________________. ✔✔Accessible
A flight of stairs shall not have a vertical rise larger than ____ feet between floor levels or landings.
✔✔12 feet
Sauna heaters shall be equipped with a thermostat that will limit room temperature to a maximum
of ______ . ✔✔194 *F
Protection of wood and wood based products from ___ shall be provided by the use of naturally
durable wood or wood that is preservative treated. ✔✔Decay
In plumbing systems, supports for 1 inch copper or copper alloy tubing run horizontal shall not be