Buckling in horizontal vinyl siding is generally caused by
a. reflected sunlight
b. improper fastening
c. condensation fastening
d. improper house
... [Show More] wrap - CORRECT ANSWER-b
At what level would water pressure within a single family dwelling begin to be
considered excessive and require correction
a. 60 psi
b. 80 psi
c. 100 psi
d. 120 psi - CORRECT ANSWER-b
A newer home with electric heat is being inspected. It has a below grade finished
basement containing a bedroom. The inspector should look for a smoke alarm and
a. an escape and rescue opening
b. a carbon monoxide alarm
c. a fire extinguisher
d. a safety ladder - CORRECT ANSWER-a
A swimming pool fence must prevent passage of a sphere that is larger than
a. 2"
b. 3"
c. 4"
d. 5" - CORRECT ANSWER-c
If water infiltration is suspected behind a finished surface. What tool would be the best
choice to verify dampness
a. an infared thermometer
b. a pin type moister meter
c. a non contact moisture meter
d. a digital camera - CORRECT ANSWER-c
Gas fired furnace heat exchanger most often fail from
a. low temperatures
b. lack of use
c. improper gas pressure
d. rust and metal fatigue - CORRECT ANSWER-d
Relative Humidity (RH) is expressed as
a. volume
b. percentage
c. capacity
d. temperature - CORRECT ANSWER-b
Connections of dissimilar metal in a plumbing systems such as galvanized steel pipe
and copper pipe, will usually cause
a. reduced water pressure
b. decreased water quality
c. glazed pipes
d. electrolysis - CORRECT ANSWER-d
A ground fault circuit interrupter (GFCI) is a safety device that
a. disconnects power when the grounding to the outlet is faulty
b. detects moisture and disconnects power in wet locations
c. disconnects the power when sensing current leakage to ground
d. protects against electrical surges and voltage spikes - CORRECT ANSWER-c
An electrical system with a fuse on the neutral conductor and on the energized
(hot)conductors
a. is twice as safe as a system where only the energized (hot) conductors are fused
b. should have the neutral conductor fuse sized to one half the normal ampacity for the
circuit
c. is overfused up to 50 % if used only for lighting
d. is hazardous and should be corrected - CORRECT ANSWER-d
To operate a central air conditioner an electric clothes dryer and an electric range the
ampacity of the service to the house should be at least
a. 100 amps at 120V
b. 125 amps at 120V
c. 60 amps at 240v
d. 100 amps at 240v - CORRECT ANSWER-d
A floor joist in a crawl space has been cut where the toilet drain passes through the
floor. The joist are 2x6 spaced 16" on center. The inspector should recommend that
a. The buyer monitor the floor. floor systems such as this have redundant framing and
removal of one joist is insignificant
b. A contractor should support the cut joist with new piers and post from below
c. The cut joist should be headed off to adjacent framing members to distribute the load.
d. A contractor be contacted to determine what is needed and make repairs -
CORRECT ANSWER-d
Most problems with concrete are caused at the time of installation. What single factor
causes the MOST problems?
a. the concrete has insufficient thickness
b. too much water is added to the mix
c. too much portland cement is in the mix
d. the wrong kind of sand is in the mix - CORRECT ANSWER-b
Brick chimneys on older properties with oil heat sometimes curve above the roof line,
with no visible cracks. Which is a possible cause of this curving?
a. settlement of the chimney footing
b. expansion of mortar
c. absence of a cricket flashing at the roof
d. lack of a rain cap on the flue - CORRECT ANSWER-b
Which set of building terms do NOT belong together?
a. cripple trimmer, purlin
b. arch, header, lintel
c. rafters, ceiling joists, trusses
d. sheathing, flooring, decking - CORRECT ANSWER-a
Which has the LEAST effect on the deflection of a dim lumber floor system?
a. joist width
b. joist grade
c. joist species
d. joist spacing - CORRECT ANSWER-a
The normal MAX rise of the residential stair treads is
a. 5 1/4"
b. 7 3/4"
c. 8 1/2"
d. 9 3/4" - CORRECT ANSWER-b
An underground receptacle may be replaced by a ground fault circuit interrupter [Show Less]