When applying the concept of surgical conscience which of the following statement should be considered? Select all that apply. - Correct Answer A. It
... [Show More] involves mental discipline & the ability to speak out
B. It is essential to the delivery of optimal care and prevent harm.
D. Surgical conscience allows for no compromise in the principles of aseptic technique.
In preparing for a regulatory survey, your quality consultant questions you about the restricted zone in your OR suite. The following statements are true: - Correct Answer A. Air flow in the OR rooms should be cleaned by HEPA filters.
C. Mask are required when open sterile supplies are present.
E. Temperature is maintained between 68 and 75 degree
F.
You are assigned to relieve a surgical technologist for lunch. You will need: - Correct Answer A. A sterile gown and gloves opened on a table (other than the main instrument table) for closed gloving.
The Joint Commission Universal Protocol consists of: Select all that apply. - Correct Answer A. Preoperative verification
B. Surgical site marking
C. Time Out
Which of the following procedures reflects best practice for transferring a medication vial to the sterile field? - Correct Answer D. Use a sterile transfer device
Which of the following practices is recommended for handling of natural absorbable suture? - Correct Answer C. Open the package carefully over a small basin to prevent splashing of the packaging solution
Recommended sponge count procedures include all of the following EXCEPT? - Correct Answer B. Counting silently so it doesn't distract other personnel.
What is the correct definition of incisional biopsy? - Correct Answer D. A small portion of tissue is incised and sent for examination.
Which of the following methods listed below may prevent mishap, event, or fire from occurring when handling electrosurgical equipment? Select all that apply. - Correct Answer A. Allow enough time for alcohol based skin preparations to completely dry.
B. Do not use in an oxygen-enriched environment, such as the trachea when oxygen is being "blown over" the patient.
D. Visually check the integrity and insulation of all cords and coagulation instruments before use. [Show Less]