Question:
When patients administer regular insulin (Humulin R U-500), they should be taught: 5 units of Humulin R U-500 is equal to 10 units on a U-100
... [Show More] insulin syringe.
10 units of Humulin R U-500 is equal to 5 units on a U-100 insulin syringe. 10 units of Humulin R U-500 is equal to 10 units on a U-500 insulin syringe. Correct
it should only be used in an insulin pump.
Explanation:
U-500 insulin is a concentrated form of insulin containing 500 units of insulin per mL. U-500 regular insulin vials are to be used only in conjunction with a dedicated U-500 insulin syringe; dosage conversion is not required with the U-500 syringe. When using a U-100 syringe or a tuberculin syringe to deliver Humulin R U-500 (from vial), a conversion step is required to ensure the correct amount of Humulin R U-500 is drawn up in the syringe. To avoid dosing errors when using a U-100 insulin syringe, the prescribed dose should be written in actual insulin units and as unit markings on the U-100 insulin syringe (e.g., Humulin R U-500 50 units = 10 units on a U-100 insulin syringe). For safety, ONLY the U-500 syringe should be used. It is not recommended for use in insulin pumps due to possibility of precipitation.
Question:
Patients taking thiazolidinedione (TZD) medications should be monitored for: diarrhea and flatulence. fluid retention and weight gain. Correct
hypotension and dizziness. weight loss and fatigue.
Explanation:
Thiazolidinediones including pioglitazone hydrochloride (Actos), may precipitate or exacerbate heart failure in some patients by causing dose-related fluid retention. After initiation of pioglitazone tablets, and after dose increases, monitor patients carefully for signs and symptoms of heart failure (e.g., excessive, rapid weight gain, dyspnea, and/or edema). If heart failure develops, pioglitazone should be discontinued or dosage reduced. Pioglitazone tablets are not recommended in patients with symptomatic heart failure. Initiation of pioglitazone hydrochloride [Show Less]